Single top quark production and Vb CKM matrix element measurement in high energy e+e- collisions

Nikolay Dokholyan, G. V. Jikia

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

A new method for the determination of the CKM mixing matrix element Vtb has been proposed. It has been shown, that at future colliders one will measure the tb-mixing element with an accuracy 12-28%.

Original languageEnglish (US)
Pages (from-to)251-256
Number of pages6
JournalPhysics Letters B
Volume336
Issue number2
DOIs
StatePublished - Sep 22 1994

Fingerprint

quarks
collisions
matrices
energy

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics

Cite this

@article{bf480a28b57b47a79a2bbd6086f64f6b,
title = "Single top quark production and Vb CKM matrix element measurement in high energy e+e- collisions",
abstract = "A new method for the determination of the CKM mixing matrix element Vtb has been proposed. It has been shown, that at future colliders one will measure the tb-mixing element with an accuracy 12-28{\%}.",
author = "Nikolay Dokholyan and Jikia, {G. V.}",
year = "1994",
month = "9",
day = "22",
doi = "10.1016/0370-2693(94)90244-5",
language = "English (US)",
volume = "336",
pages = "251--256",
journal = "Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics",
issn = "0370-2693",
publisher = "Elsevier",
number = "2",

}

Single top quark production and Vb CKM matrix element measurement in high energy e+e- collisions. / Dokholyan, Nikolay; Jikia, G. V.

In: Physics Letters B, Vol. 336, No. 2, 22.09.1994, p. 251-256.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Single top quark production and Vb CKM matrix element measurement in high energy e+e- collisions

AU - Dokholyan, Nikolay

AU - Jikia, G. V.

PY - 1994/9/22

Y1 - 1994/9/22

N2 - A new method for the determination of the CKM mixing matrix element Vtb has been proposed. It has been shown, that at future colliders one will measure the tb-mixing element with an accuracy 12-28%.

AB - A new method for the determination of the CKM mixing matrix element Vtb has been proposed. It has been shown, that at future colliders one will measure the tb-mixing element with an accuracy 12-28%.

UR - http://www.scopus.com/inward/record.url?scp=0006647177&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0006647177&partnerID=8YFLogxK

U2 - 10.1016/0370-2693(94)90244-5

DO - 10.1016/0370-2693(94)90244-5

M3 - Article

VL - 336

SP - 251

EP - 256

JO - Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics

JF - Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics

SN - 0370-2693

IS - 2

ER -