Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry

Robert M. Braun, Arthur Beyder, Jiyun Xu, Mark C. Wood, Andrew G. Ewing, Nicholas Winograd

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been utilized to detect femtomole and attomole quantities of organic species from within silicon nanovials. By using high-density arrays (10 000 nanovials/cm 2 ) it is possible to chemically characterize diverse sample sets within a single chemical image. Molecular sensitivities, for the compounds investigated, vary between 85 attomoles and 25 femtomoles, and typical acquisition times are approximately 100 ms per nanovial. These vials are fabricated using photolithography and KOH etching of Si{001} wafers to create wells, with a pyramidal cross section, ranging in size from 25 to 5625 μm 2 . The volume ranges from 30 femtoliters to 100 picoliters, respectively. A drawn glass microinjector and solenoid-driven dispenser are utilized to array picoliter volumes of organic compounds into individual silicon nanovials. Solution concentrations typically range from 1 x 10 -2 to 1 x 10 -4 M allowing femtomole and even attomole quantities of material to be dispensed into each vial.

Original languageEnglish (US)
Pages (from-to)3318-3324
Number of pages7
JournalAnalytical Chemistry
Volume71
Issue number16
DOIs
StatePublished - Aug 15 1999

Fingerprint

Silicon
Secondary ion mass spectrometry
Dispensers
Molecules
Solenoids
Photolithography
Organic compounds
Etching
Glass

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

Braun, Robert M. ; Beyder, Arthur ; Xu, Jiyun ; Wood, Mark C. ; Ewing, Andrew G. ; Winograd, Nicholas. / Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry. In: Analytical Chemistry. 1999 ; Vol. 71, No. 16. pp. 3318-3324.
@article{59db8872e8a3485a92ebb54e899df180,
title = "Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry",
abstract = "Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been utilized to detect femtomole and attomole quantities of organic species from within silicon nanovials. By using high-density arrays (10 000 nanovials/cm 2 ) it is possible to chemically characterize diverse sample sets within a single chemical image. Molecular sensitivities, for the compounds investigated, vary between 85 attomoles and 25 femtomoles, and typical acquisition times are approximately 100 ms per nanovial. These vials are fabricated using photolithography and KOH etching of Si{001} wafers to create wells, with a pyramidal cross section, ranging in size from 25 to 5625 μm 2 . The volume ranges from 30 femtoliters to 100 picoliters, respectively. A drawn glass microinjector and solenoid-driven dispenser are utilized to array picoliter volumes of organic compounds into individual silicon nanovials. Solution concentrations typically range from 1 x 10 -2 to 1 x 10 -4 M allowing femtomole and even attomole quantities of material to be dispensed into each vial.",
author = "Braun, {Robert M.} and Arthur Beyder and Jiyun Xu and Wood, {Mark C.} and Ewing, {Andrew G.} and Nicholas Winograd",
year = "1999",
month = "8",
day = "15",
doi = "10.1021/ac9902042",
language = "English (US)",
volume = "71",
pages = "3318--3324",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "16",

}

Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry. / Braun, Robert M.; Beyder, Arthur; Xu, Jiyun; Wood, Mark C.; Ewing, Andrew G.; Winograd, Nicholas.

In: Analytical Chemistry, Vol. 71, No. 16, 15.08.1999, p. 3318-3324.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry

AU - Braun, Robert M.

AU - Beyder, Arthur

AU - Xu, Jiyun

AU - Wood, Mark C.

AU - Ewing, Andrew G.

AU - Winograd, Nicholas

PY - 1999/8/15

Y1 - 1999/8/15

N2 - Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been utilized to detect femtomole and attomole quantities of organic species from within silicon nanovials. By using high-density arrays (10 000 nanovials/cm 2 ) it is possible to chemically characterize diverse sample sets within a single chemical image. Molecular sensitivities, for the compounds investigated, vary between 85 attomoles and 25 femtomoles, and typical acquisition times are approximately 100 ms per nanovial. These vials are fabricated using photolithography and KOH etching of Si{001} wafers to create wells, with a pyramidal cross section, ranging in size from 25 to 5625 μm 2 . The volume ranges from 30 femtoliters to 100 picoliters, respectively. A drawn glass microinjector and solenoid-driven dispenser are utilized to array picoliter volumes of organic compounds into individual silicon nanovials. Solution concentrations typically range from 1 x 10 -2 to 1 x 10 -4 M allowing femtomole and even attomole quantities of material to be dispensed into each vial.

AB - Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been utilized to detect femtomole and attomole quantities of organic species from within silicon nanovials. By using high-density arrays (10 000 nanovials/cm 2 ) it is possible to chemically characterize diverse sample sets within a single chemical image. Molecular sensitivities, for the compounds investigated, vary between 85 attomoles and 25 femtomoles, and typical acquisition times are approximately 100 ms per nanovial. These vials are fabricated using photolithography and KOH etching of Si{001} wafers to create wells, with a pyramidal cross section, ranging in size from 25 to 5625 μm 2 . The volume ranges from 30 femtoliters to 100 picoliters, respectively. A drawn glass microinjector and solenoid-driven dispenser are utilized to array picoliter volumes of organic compounds into individual silicon nanovials. Solution concentrations typically range from 1 x 10 -2 to 1 x 10 -4 M allowing femtomole and even attomole quantities of material to be dispensed into each vial.

UR - http://www.scopus.com/inward/record.url?scp=0033566589&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033566589&partnerID=8YFLogxK

U2 - 10.1021/ac9902042

DO - 10.1021/ac9902042

M3 - Article

C2 - 10464472

AN - SCOPUS:0033566589

VL - 71

SP - 3318

EP - 3324

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 16

ER -