SU‐C‐217A‐06

A Collaborative Approach to Dose Optimization in Fluoroscopy Guided Lumbar Spine Injection Procedures

K. Brown, Paul Kalapos, Dan Thach Nguyen, Krishnamoorthy Thamburaj, T. Rahman

Research output: Contribution to journalArticle

Abstract

Purpose: To observe and evaluate technical acquisition and operating procedures used for lumbar spine injection procedures under fluoroscopy guidance performed by multiple neuroradiologists for potential patient dose reduction opportunities. Methods: Baseline skin dose measurements were acquired on patients undergoing lumbar spine injection procedures on a biplane fluoroscopy unit. Optically stimulated luminescent dosimeters were placed on the patient's abdomen corresponding to the anterior‐posterior plane beam entrance location and on the patient's right side corresponding to the lateral plane beam entrance location. Technical acquisition factors, treated levels, and patient demographics were recorded. In addition, observations were made of operating procedures such as the use of collimation and magnification, patient and equipment positioning, beam angulations, and exposure techniques used by individual neuroradiologists. Results: Baseline data and observations were reviewed with neuroradiologists. Opportunities to reduce dose were discussed and a series of acquisition and practice changes accepted. Changes were implemented and skin dose measurements repeated. Results showed a reduction in skin dose of 64% and 79% respectively for anterior‐posterior and lateral planes from baseline data. No adverse outcomes to procedure time, fluoroscopy time, or image quality were observed. Conclusions: Practices among physicians can vary substantially. Collaboration and standardization of acquisition and operating procedures can Result in substantial dose reduction for patients without compromising image quality or clinical productivity.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume39
Issue number6
DOIs
StatePublished - Jan 1 2012

Fingerprint

Fluoroscopy
Spine
Injections
Skin
Patient Positioning
Patient Rights
Abdomen
Demography
Physicians
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

@article{7b9d19477c3f4de48eea21c08a37b83d,
title = "SU‐C‐217A‐06: A Collaborative Approach to Dose Optimization in Fluoroscopy Guided Lumbar Spine Injection Procedures",
abstract = "Purpose: To observe and evaluate technical acquisition and operating procedures used for lumbar spine injection procedures under fluoroscopy guidance performed by multiple neuroradiologists for potential patient dose reduction opportunities. Methods: Baseline skin dose measurements were acquired on patients undergoing lumbar spine injection procedures on a biplane fluoroscopy unit. Optically stimulated luminescent dosimeters were placed on the patient's abdomen corresponding to the anterior‐posterior plane beam entrance location and on the patient's right side corresponding to the lateral plane beam entrance location. Technical acquisition factors, treated levels, and patient demographics were recorded. In addition, observations were made of operating procedures such as the use of collimation and magnification, patient and equipment positioning, beam angulations, and exposure techniques used by individual neuroradiologists. Results: Baseline data and observations were reviewed with neuroradiologists. Opportunities to reduce dose were discussed and a series of acquisition and practice changes accepted. Changes were implemented and skin dose measurements repeated. Results showed a reduction in skin dose of 64{\%} and 79{\%} respectively for anterior‐posterior and lateral planes from baseline data. No adverse outcomes to procedure time, fluoroscopy time, or image quality were observed. Conclusions: Practices among physicians can vary substantially. Collaboration and standardization of acquisition and operating procedures can Result in substantial dose reduction for patients without compromising image quality or clinical productivity.",
author = "K. Brown and Paul Kalapos and Nguyen, {Dan Thach} and Krishnamoorthy Thamburaj and T. Rahman",
year = "2012",
month = "1",
day = "1",
doi = "10.1118/1.4734648",
language = "English (US)",
volume = "39",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

SU‐C‐217A‐06 : A Collaborative Approach to Dose Optimization in Fluoroscopy Guided Lumbar Spine Injection Procedures. / Brown, K.; Kalapos, Paul; Nguyen, Dan Thach; Thamburaj, Krishnamoorthy; Rahman, T.

In: Medical Physics, Vol. 39, No. 6, 01.01.2012.

Research output: Contribution to journalArticle

TY - JOUR

T1 - SU‐C‐217A‐06

T2 - A Collaborative Approach to Dose Optimization in Fluoroscopy Guided Lumbar Spine Injection Procedures

AU - Brown, K.

AU - Kalapos, Paul

AU - Nguyen, Dan Thach

AU - Thamburaj, Krishnamoorthy

AU - Rahman, T.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Purpose: To observe and evaluate technical acquisition and operating procedures used for lumbar spine injection procedures under fluoroscopy guidance performed by multiple neuroradiologists for potential patient dose reduction opportunities. Methods: Baseline skin dose measurements were acquired on patients undergoing lumbar spine injection procedures on a biplane fluoroscopy unit. Optically stimulated luminescent dosimeters were placed on the patient's abdomen corresponding to the anterior‐posterior plane beam entrance location and on the patient's right side corresponding to the lateral plane beam entrance location. Technical acquisition factors, treated levels, and patient demographics were recorded. In addition, observations were made of operating procedures such as the use of collimation and magnification, patient and equipment positioning, beam angulations, and exposure techniques used by individual neuroradiologists. Results: Baseline data and observations were reviewed with neuroradiologists. Opportunities to reduce dose were discussed and a series of acquisition and practice changes accepted. Changes were implemented and skin dose measurements repeated. Results showed a reduction in skin dose of 64% and 79% respectively for anterior‐posterior and lateral planes from baseline data. No adverse outcomes to procedure time, fluoroscopy time, or image quality were observed. Conclusions: Practices among physicians can vary substantially. Collaboration and standardization of acquisition and operating procedures can Result in substantial dose reduction for patients without compromising image quality or clinical productivity.

AB - Purpose: To observe and evaluate technical acquisition and operating procedures used for lumbar spine injection procedures under fluoroscopy guidance performed by multiple neuroradiologists for potential patient dose reduction opportunities. Methods: Baseline skin dose measurements were acquired on patients undergoing lumbar spine injection procedures on a biplane fluoroscopy unit. Optically stimulated luminescent dosimeters were placed on the patient's abdomen corresponding to the anterior‐posterior plane beam entrance location and on the patient's right side corresponding to the lateral plane beam entrance location. Technical acquisition factors, treated levels, and patient demographics were recorded. In addition, observations were made of operating procedures such as the use of collimation and magnification, patient and equipment positioning, beam angulations, and exposure techniques used by individual neuroradiologists. Results: Baseline data and observations were reviewed with neuroradiologists. Opportunities to reduce dose were discussed and a series of acquisition and practice changes accepted. Changes were implemented and skin dose measurements repeated. Results showed a reduction in skin dose of 64% and 79% respectively for anterior‐posterior and lateral planes from baseline data. No adverse outcomes to procedure time, fluoroscopy time, or image quality were observed. Conclusions: Practices among physicians can vary substantially. Collaboration and standardization of acquisition and operating procedures can Result in substantial dose reduction for patients without compromising image quality or clinical productivity.

UR - http://www.scopus.com/inward/record.url?scp=85024789736&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024789736&partnerID=8YFLogxK

U2 - 10.1118/1.4734648

DO - 10.1118/1.4734648

M3 - Article

VL - 39

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -