Testing of actively cooled high heat flux mock-ups

M. Rödig, R. Duwe, W. Kühnlein, J. Linke, M. Scheerer, I. Smid, B. Wiechers

Research output: Contribution to journalArticle

6 Scopus citations

Abstract

Several un-irradiated CFC monoblock mock-ups have been loaded in thermal fatigue tests up to 1000 cycles at power densities <25 MW/m2. No indication of failure was observed for these loading conditions. Two of the mock-ups were inspected by ultra-sonic methods before thermal cycling. It could be proved that the voids found in the post-mortem metallography existed before and had no effect on the integrity of the mock-up. For the first time, neutron-irradiated CFC monoblock mock-ups have been tested in the electron beam facility JUDITH. These mock-ups had been irradiated before in the High Flux Reactor at Petten up to 0.3 dpa at 320°C and 770°C. All samples showed a significant increase of surface temperature, due to the irradiation induced decrease in thermal conductivity of the CFC materials.

Original languageEnglish (US)
Pages (from-to)967-971
Number of pages5
JournalJournal of Nuclear Materials
Volume258-263
Issue numberPART 1 A
DOIs
StatePublished - Oct 1998

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Materials Science(all)
  • Nuclear Energy and Engineering

Fingerprint Dive into the research topics of 'Testing of actively cooled high heat flux mock-ups'. Together they form a unique fingerprint.

  • Cite this

    Rödig, M., Duwe, R., Kühnlein, W., Linke, J., Scheerer, M., Smid, I., & Wiechers, B. (1998). Testing of actively cooled high heat flux mock-ups. Journal of Nuclear Materials, 258-263(PART 1 A), 967-971. https://doi.org/10.1016/S0022-3115(98)00081-6