Therapeutic dose from a pyroelectric electron accelerator.

T. Z. Fullem, K. C. Fazel, Jeffrey Geuther, Y. Danon

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Simple heating of pyroelectric crystals has been used as the basis for compact sources of X rays, electrons, ions and neutrons. We report on the evaluation of the feasibility of using a portable pyroelectric electron accelerator to deliver a therapeutic dose to tissue. Such a device could be mass produced as a handheld, battery-powered instrument. Experiments were conducted with several crystal sizes in which the crystal was heated inside a vacuum chamber and the emitted electrons were allowed to penetrate a thin beryllium window into the surrounding air. A Faraday cup was used to count the number of electrons that exited the window. The energy of these electrons was determined by measuring the energy spectrum of the X rays that resulted from the electron interactions with the Faraday cup. Based on these measurements, the dose that this source could deliver to tissue was calculated using Monte Carlo calculations. It was found that 10(13) electrons with a peak energy of the order of 100 keV were emitted from the beryllium window and could deliver a dose of 1664 Gy to a 2-cm-diameter, 110-microm-deep region of tissue located 1.5 cm from the window with air between the window and the tissue. This dose level is high enough to consider this technology for medical applications in which shallow energy deposition is beneficial.

Original languageEnglish (US)
Pages (from-to)643-647
Number of pages5
JournalRadiation research
Volume172
Issue number5
DOIs
StatePublished - Jan 1 2009

Fingerprint

electron accelerators
Electrons
dosage
beryllium
electrons
Beryllium
crystals
Therapeutics
air
Air
X-Rays
vacuum chambers
electric batteries
energy
electron scattering
energy spectra
x rays
Neutrons
Vacuum
Heating

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Radiation
  • Radiology Nuclear Medicine and imaging

Cite this

Fullem, T. Z. ; Fazel, K. C. ; Geuther, Jeffrey ; Danon, Y. / Therapeutic dose from a pyroelectric electron accelerator. In: Radiation research. 2009 ; Vol. 172, No. 5. pp. 643-647.
@article{9dbd9de5442b447fa6e6a88b30e2a4b0,
title = "Therapeutic dose from a pyroelectric electron accelerator.",
abstract = "Simple heating of pyroelectric crystals has been used as the basis for compact sources of X rays, electrons, ions and neutrons. We report on the evaluation of the feasibility of using a portable pyroelectric electron accelerator to deliver a therapeutic dose to tissue. Such a device could be mass produced as a handheld, battery-powered instrument. Experiments were conducted with several crystal sizes in which the crystal was heated inside a vacuum chamber and the emitted electrons were allowed to penetrate a thin beryllium window into the surrounding air. A Faraday cup was used to count the number of electrons that exited the window. The energy of these electrons was determined by measuring the energy spectrum of the X rays that resulted from the electron interactions with the Faraday cup. Based on these measurements, the dose that this source could deliver to tissue was calculated using Monte Carlo calculations. It was found that 10(13) electrons with a peak energy of the order of 100 keV were emitted from the beryllium window and could deliver a dose of 1664 Gy to a 2-cm-diameter, 110-microm-deep region of tissue located 1.5 cm from the window with air between the window and the tissue. This dose level is high enough to consider this technology for medical applications in which shallow energy deposition is beneficial.",
author = "Fullem, {T. Z.} and Fazel, {K. C.} and Jeffrey Geuther and Y. Danon",
year = "2009",
month = "1",
day = "1",
doi = "10.1667/RR1876.1",
language = "English (US)",
volume = "172",
pages = "643--647",
journal = "Radiation Research",
issn = "0033-7587",
publisher = "Radiation Research Society",
number = "5",

}

Therapeutic dose from a pyroelectric electron accelerator. / Fullem, T. Z.; Fazel, K. C.; Geuther, Jeffrey; Danon, Y.

In: Radiation research, Vol. 172, No. 5, 01.01.2009, p. 643-647.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Therapeutic dose from a pyroelectric electron accelerator.

AU - Fullem, T. Z.

AU - Fazel, K. C.

AU - Geuther, Jeffrey

AU - Danon, Y.

PY - 2009/1/1

Y1 - 2009/1/1

N2 - Simple heating of pyroelectric crystals has been used as the basis for compact sources of X rays, electrons, ions and neutrons. We report on the evaluation of the feasibility of using a portable pyroelectric electron accelerator to deliver a therapeutic dose to tissue. Such a device could be mass produced as a handheld, battery-powered instrument. Experiments were conducted with several crystal sizes in which the crystal was heated inside a vacuum chamber and the emitted electrons were allowed to penetrate a thin beryllium window into the surrounding air. A Faraday cup was used to count the number of electrons that exited the window. The energy of these electrons was determined by measuring the energy spectrum of the X rays that resulted from the electron interactions with the Faraday cup. Based on these measurements, the dose that this source could deliver to tissue was calculated using Monte Carlo calculations. It was found that 10(13) electrons with a peak energy of the order of 100 keV were emitted from the beryllium window and could deliver a dose of 1664 Gy to a 2-cm-diameter, 110-microm-deep region of tissue located 1.5 cm from the window with air between the window and the tissue. This dose level is high enough to consider this technology for medical applications in which shallow energy deposition is beneficial.

AB - Simple heating of pyroelectric crystals has been used as the basis for compact sources of X rays, electrons, ions and neutrons. We report on the evaluation of the feasibility of using a portable pyroelectric electron accelerator to deliver a therapeutic dose to tissue. Such a device could be mass produced as a handheld, battery-powered instrument. Experiments were conducted with several crystal sizes in which the crystal was heated inside a vacuum chamber and the emitted electrons were allowed to penetrate a thin beryllium window into the surrounding air. A Faraday cup was used to count the number of electrons that exited the window. The energy of these electrons was determined by measuring the energy spectrum of the X rays that resulted from the electron interactions with the Faraday cup. Based on these measurements, the dose that this source could deliver to tissue was calculated using Monte Carlo calculations. It was found that 10(13) electrons with a peak energy of the order of 100 keV were emitted from the beryllium window and could deliver a dose of 1664 Gy to a 2-cm-diameter, 110-microm-deep region of tissue located 1.5 cm from the window with air between the window and the tissue. This dose level is high enough to consider this technology for medical applications in which shallow energy deposition is beneficial.

UR - http://www.scopus.com/inward/record.url?scp=70449732513&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449732513&partnerID=8YFLogxK

U2 - 10.1667/RR1876.1

DO - 10.1667/RR1876.1

M3 - Article

C2 - 19883233

AN - SCOPUS:70449732513

VL - 172

SP - 643

EP - 647

JO - Radiation Research

JF - Radiation Research

SN - 0033-7587

IS - 5

ER -