Abstract

Finite element analysis was used to calculate the static magnetic field within the three-dimensional head model. Localized field distributions were evaluated by using the magnetic field histogram technique. Experimental field maps and histograms of the human head were also obtained to validate the simulation results. Field deviations and gradients inside the human head cause NMR signal frequency shifts and line broadening, respectively. Voxels 2 x 2 x 0.5 cm may have frequency differences of more than 2.0 ppm. The linewidth of a single voxel may be broadened by more than 0.5 ppm. Calculated and experimental field maps are in excellent agreement. The global field distortion in the human head is primarily due to the susceptibility difference between air and tissues and their corresponding geometrical shapes.

Original languageEnglish (US)
Pages (from-to)705-714
Number of pages10
JournalMagnetic Resonance in Medicine
Volume36
Issue number5
DOIs
StatePublished - Nov 1 1996

Fingerprint

Magnetic Fields
Head
Finite Element Analysis
Air

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

Li, Shizhe ; Dardzinski, Bernard J. ; Collins, Christopher M. ; Yang, Qing ; Smith, Michael B. / Three-dimensional mapping of the static magnetic field inside the human head. In: Magnetic Resonance in Medicine. 1996 ; Vol. 36, No. 5. pp. 705-714.
@article{950a053a3e59422681580943372cf01a,
title = "Three-dimensional mapping of the static magnetic field inside the human head",
abstract = "Finite element analysis was used to calculate the static magnetic field within the three-dimensional head model. Localized field distributions were evaluated by using the magnetic field histogram technique. Experimental field maps and histograms of the human head were also obtained to validate the simulation results. Field deviations and gradients inside the human head cause NMR signal frequency shifts and line broadening, respectively. Voxels 2 x 2 x 0.5 cm may have frequency differences of more than 2.0 ppm. The linewidth of a single voxel may be broadened by more than 0.5 ppm. Calculated and experimental field maps are in excellent agreement. The global field distortion in the human head is primarily due to the susceptibility difference between air and tissues and their corresponding geometrical shapes.",
author = "Shizhe Li and Dardzinski, {Bernard J.} and Collins, {Christopher M.} and Qing Yang and Smith, {Michael B.}",
year = "1996",
month = "11",
day = "1",
doi = "10.1002/mrm.1910360509",
language = "English (US)",
volume = "36",
pages = "705--714",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

Three-dimensional mapping of the static magnetic field inside the human head. / Li, Shizhe; Dardzinski, Bernard J.; Collins, Christopher M.; Yang, Qing; Smith, Michael B.

In: Magnetic Resonance in Medicine, Vol. 36, No. 5, 01.11.1996, p. 705-714.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Three-dimensional mapping of the static magnetic field inside the human head

AU - Li, Shizhe

AU - Dardzinski, Bernard J.

AU - Collins, Christopher M.

AU - Yang, Qing

AU - Smith, Michael B.

PY - 1996/11/1

Y1 - 1996/11/1

N2 - Finite element analysis was used to calculate the static magnetic field within the three-dimensional head model. Localized field distributions were evaluated by using the magnetic field histogram technique. Experimental field maps and histograms of the human head were also obtained to validate the simulation results. Field deviations and gradients inside the human head cause NMR signal frequency shifts and line broadening, respectively. Voxels 2 x 2 x 0.5 cm may have frequency differences of more than 2.0 ppm. The linewidth of a single voxel may be broadened by more than 0.5 ppm. Calculated and experimental field maps are in excellent agreement. The global field distortion in the human head is primarily due to the susceptibility difference between air and tissues and their corresponding geometrical shapes.

AB - Finite element analysis was used to calculate the static magnetic field within the three-dimensional head model. Localized field distributions were evaluated by using the magnetic field histogram technique. Experimental field maps and histograms of the human head were also obtained to validate the simulation results. Field deviations and gradients inside the human head cause NMR signal frequency shifts and line broadening, respectively. Voxels 2 x 2 x 0.5 cm may have frequency differences of more than 2.0 ppm. The linewidth of a single voxel may be broadened by more than 0.5 ppm. Calculated and experimental field maps are in excellent agreement. The global field distortion in the human head is primarily due to the susceptibility difference between air and tissues and their corresponding geometrical shapes.

UR - http://www.scopus.com/inward/record.url?scp=0029911435&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029911435&partnerID=8YFLogxK

U2 - 10.1002/mrm.1910360509

DO - 10.1002/mrm.1910360509

M3 - Article

C2 - 8916021

AN - SCOPUS:0029911435

VL - 36

SP - 705

EP - 714

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -