Two-photon excitation fluorescence imaging by using wavelength division scanning

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

We demonstrate a new wavelength-division scanning method for two-photon excitation fluorescence imaging. Two-photon imaging results using lateral wavelength division scanning are presented. Feasibility of axial wavelength division scanning is discussed.

Original languageEnglish (US)
Title of host publicationConference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006
DOIs
StatePublished - 2006
EventConference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006 - Long Beach, CA, United States
Duration: May 21 2006May 26 2006

Other

OtherConference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006
CountryUnited States
CityLong Beach, CA
Period5/21/065/26/06

Fingerprint

division
Photons
Fluorescence
Scanning
Imaging techniques
Wavelength
fluorescence
scanning
photons
wavelengths
excitation

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering
  • Atomic and Molecular Physics, and Optics

Cite this

Shi, K., Yin, S., & Liu, Z. (2006). Two-photon excitation fluorescence imaging by using wavelength division scanning. In Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006 [4627826] https://doi.org/10.1109/CLEO.2006.4627826
Shi, Kebin ; Yin, Shizhuo ; Liu, Zhiwen. / Two-photon excitation fluorescence imaging by using wavelength division scanning. Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006. 2006.
@inproceedings{be3c13863076482a9b762744dc0a3c40,
title = "Two-photon excitation fluorescence imaging by using wavelength division scanning",
abstract = "We demonstrate a new wavelength-division scanning method for two-photon excitation fluorescence imaging. Two-photon imaging results using lateral wavelength division scanning are presented. Feasibility of axial wavelength division scanning is discussed.",
author = "Kebin Shi and Shizhuo Yin and Zhiwen Liu",
year = "2006",
doi = "10.1109/CLEO.2006.4627826",
language = "English (US)",
isbn = "1557528136",
booktitle = "Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006",

}

Shi, K, Yin, S & Liu, Z 2006, Two-photon excitation fluorescence imaging by using wavelength division scanning. in Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006., 4627826, Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006, Long Beach, CA, United States, 5/21/06. https://doi.org/10.1109/CLEO.2006.4627826

Two-photon excitation fluorescence imaging by using wavelength division scanning. / Shi, Kebin; Yin, Shizhuo; Liu, Zhiwen.

Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006. 2006. 4627826.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Two-photon excitation fluorescence imaging by using wavelength division scanning

AU - Shi, Kebin

AU - Yin, Shizhuo

AU - Liu, Zhiwen

PY - 2006

Y1 - 2006

N2 - We demonstrate a new wavelength-division scanning method for two-photon excitation fluorescence imaging. Two-photon imaging results using lateral wavelength division scanning are presented. Feasibility of axial wavelength division scanning is discussed.

AB - We demonstrate a new wavelength-division scanning method for two-photon excitation fluorescence imaging. Two-photon imaging results using lateral wavelength division scanning are presented. Feasibility of axial wavelength division scanning is discussed.

UR - http://www.scopus.com/inward/record.url?scp=55649086503&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=55649086503&partnerID=8YFLogxK

U2 - 10.1109/CLEO.2006.4627826

DO - 10.1109/CLEO.2006.4627826

M3 - Conference contribution

SN - 1557528136

SN - 9781557528131

BT - Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006

ER -

Shi K, Yin S, Liu Z. Two-photon excitation fluorescence imaging by using wavelength division scanning. In Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference, CLEO/QELS 2006. 2006. 4627826 https://doi.org/10.1109/CLEO.2006.4627826