Use of a plasma dual isotope ratio method to measure vitamin A absorption

Michael Henry Green, J. B. Green

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

We evaluated the possibility of modifying a method for cholesterol absorption (ABSN) (Zilversmit, D.B., Proc. Soc. Exp. Biol. Med. 140:862, 1972) to measure ABSN of vitamin A (VIT A). Adult male Sprague-Dawley rats (n = 14; liver VIT A ∼2200 nmol) received an IV dose of [14C]vitamin A- labeled lymph to label body pools; simultaneously [3H]vitamin A in soy oil was given orally. Blood was sampled on d 1, 2, 3, 6, 9 and 12. VIT A ABSN was estimated as 100 * the plasma ratio of [3H]/[14C] (normalized to doses administered). Apparent ABSN ranged from 132-330% on d 1 (perhaps because the VIT A load in the IV dose was high [77 nmol]). However, by d 6, ratios were stabilizing and ABSN was 74 ± 5% (mean ± SD) on d 12. For comparison, VIT A ABSN measured directly in lymph duct-cannulated rats was 76 ± 16% (n = 11) (Allen, LE. et al., Canc. Res. 54:3319, 1994). We conclude that the plasma dual isotope ratio method may be a simple and accurate new method for measuring VIT A ABSN. Plasma must be sampled after the ratio has stabilized (predicted to be 14 d for these data), and VIT A mass in the doses should be as small as possible. A modified method, using stable isotopes or non-radioactive analogues, may be useful for estimating VIT A ABSN in humans based on a single blood sample. (Supported by USDA CRG 9500618).

Original languageEnglish (US)
JournalFASEB Journal
Volume11
Issue number3
StatePublished - Dec 1 1997

Fingerprint

Vitamin A
Isotopes
Plasmas
Lymph
Rats
Blood
United States Department of Agriculture
Liver
Ducts
Sprague Dawley Rats
Labels
Oils
Cholesterol

All Science Journal Classification (ASJC) codes

  • Biotechnology
  • Biochemistry
  • Molecular Biology
  • Genetics

Cite this

Green, Michael Henry ; Green, J. B. / Use of a plasma dual isotope ratio method to measure vitamin A absorption. In: FASEB Journal. 1997 ; Vol. 11, No. 3.
@article{bcb297da6d5342f7a216440d3a475b46,
title = "Use of a plasma dual isotope ratio method to measure vitamin A absorption",
abstract = "We evaluated the possibility of modifying a method for cholesterol absorption (ABSN) (Zilversmit, D.B., Proc. Soc. Exp. Biol. Med. 140:862, 1972) to measure ABSN of vitamin A (VIT A). Adult male Sprague-Dawley rats (n = 14; liver VIT A ∼2200 nmol) received an IV dose of [14C]vitamin A- labeled lymph to label body pools; simultaneously [3H]vitamin A in soy oil was given orally. Blood was sampled on d 1, 2, 3, 6, 9 and 12. VIT A ABSN was estimated as 100 * the plasma ratio of [3H]/[14C] (normalized to doses administered). Apparent ABSN ranged from 132-330{\%} on d 1 (perhaps because the VIT A load in the IV dose was high [77 nmol]). However, by d 6, ratios were stabilizing and ABSN was 74 ± 5{\%} (mean ± SD) on d 12. For comparison, VIT A ABSN measured directly in lymph duct-cannulated rats was 76 ± 16{\%} (n = 11) (Allen, LE. et al., Canc. Res. 54:3319, 1994). We conclude that the plasma dual isotope ratio method may be a simple and accurate new method for measuring VIT A ABSN. Plasma must be sampled after the ratio has stabilized (predicted to be 14 d for these data), and VIT A mass in the doses should be as small as possible. A modified method, using stable isotopes or non-radioactive analogues, may be useful for estimating VIT A ABSN in humans based on a single blood sample. (Supported by USDA CRG 9500618).",
author = "Green, {Michael Henry} and Green, {J. B.}",
year = "1997",
month = "12",
day = "1",
language = "English (US)",
volume = "11",
journal = "FASEB Journal",
issn = "0892-6638",
publisher = "FASEB",
number = "3",

}

Use of a plasma dual isotope ratio method to measure vitamin A absorption. / Green, Michael Henry; Green, J. B.

In: FASEB Journal, Vol. 11, No. 3, 01.12.1997.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Use of a plasma dual isotope ratio method to measure vitamin A absorption

AU - Green, Michael Henry

AU - Green, J. B.

PY - 1997/12/1

Y1 - 1997/12/1

N2 - We evaluated the possibility of modifying a method for cholesterol absorption (ABSN) (Zilversmit, D.B., Proc. Soc. Exp. Biol. Med. 140:862, 1972) to measure ABSN of vitamin A (VIT A). Adult male Sprague-Dawley rats (n = 14; liver VIT A ∼2200 nmol) received an IV dose of [14C]vitamin A- labeled lymph to label body pools; simultaneously [3H]vitamin A in soy oil was given orally. Blood was sampled on d 1, 2, 3, 6, 9 and 12. VIT A ABSN was estimated as 100 * the plasma ratio of [3H]/[14C] (normalized to doses administered). Apparent ABSN ranged from 132-330% on d 1 (perhaps because the VIT A load in the IV dose was high [77 nmol]). However, by d 6, ratios were stabilizing and ABSN was 74 ± 5% (mean ± SD) on d 12. For comparison, VIT A ABSN measured directly in lymph duct-cannulated rats was 76 ± 16% (n = 11) (Allen, LE. et al., Canc. Res. 54:3319, 1994). We conclude that the plasma dual isotope ratio method may be a simple and accurate new method for measuring VIT A ABSN. Plasma must be sampled after the ratio has stabilized (predicted to be 14 d for these data), and VIT A mass in the doses should be as small as possible. A modified method, using stable isotopes or non-radioactive analogues, may be useful for estimating VIT A ABSN in humans based on a single blood sample. (Supported by USDA CRG 9500618).

AB - We evaluated the possibility of modifying a method for cholesterol absorption (ABSN) (Zilversmit, D.B., Proc. Soc. Exp. Biol. Med. 140:862, 1972) to measure ABSN of vitamin A (VIT A). Adult male Sprague-Dawley rats (n = 14; liver VIT A ∼2200 nmol) received an IV dose of [14C]vitamin A- labeled lymph to label body pools; simultaneously [3H]vitamin A in soy oil was given orally. Blood was sampled on d 1, 2, 3, 6, 9 and 12. VIT A ABSN was estimated as 100 * the plasma ratio of [3H]/[14C] (normalized to doses administered). Apparent ABSN ranged from 132-330% on d 1 (perhaps because the VIT A load in the IV dose was high [77 nmol]). However, by d 6, ratios were stabilizing and ABSN was 74 ± 5% (mean ± SD) on d 12. For comparison, VIT A ABSN measured directly in lymph duct-cannulated rats was 76 ± 16% (n = 11) (Allen, LE. et al., Canc. Res. 54:3319, 1994). We conclude that the plasma dual isotope ratio method may be a simple and accurate new method for measuring VIT A ABSN. Plasma must be sampled after the ratio has stabilized (predicted to be 14 d for these data), and VIT A mass in the doses should be as small as possible. A modified method, using stable isotopes or non-radioactive analogues, may be useful for estimating VIT A ABSN in humans based on a single blood sample. (Supported by USDA CRG 9500618).

UR - http://www.scopus.com/inward/record.url?scp=33750122560&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750122560&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:33750122560

VL - 11

JO - FASEB Journal

JF - FASEB Journal

SN - 0892-6638

IS - 3

ER -