The development of a vibration isolation system for a magnetic resonance imaging facility, University of Pittsburgh Medical Center (UPMC) Sports Performance Center, that was installed 50 ft from a busy heavy freight rail line is discussed. The UPMC wanted to eliminate all MRI operational disruptions caused by train traffic. An important task was to characterize the ground vibration at the MRI site due to the train traffic. The isolation system used an iterative process to optimize the design with regard to reduce vibration and cost. The vibration isolation approach required placing the MRI on a large inertial mass supported by a suspension with low rigid body resonant frequencies. The proposed UPMC Sports Performance Center also required to place the entire MRI room on an inertial mass and suspending it on a bed of helical coil. The continuous design refinement helped maximize isolation performance and periodic inspections ensured that isolation performance were not compromised.

Original languageEnglish (US)
Pages10-19
Number of pages10
Volume40
No12
Specialist publicationSound and Vibration
StatePublished - Dec 1 2006

Fingerprint

Magnetic resonance imaging
isolation
vibration
Sports
traffic
Magnetic resonance
cargo
Vibrations (mechanical)
Rails
rails
Natural frequencies
rigid structures
Inspection
rooms
magnetic resonance
resonant frequencies
beds
inspection
Imaging techniques
coils

All Science Journal Classification (ASJC) codes

  • Safety, Risk, Reliability and Quality
  • Acoustics and Ultrasonics
  • Mechanical Engineering

Cite this

Thornton, W. R., Trethewey, M. W., Maynard, K. P., & Sadler, J. F. (2006). Vibration isolation of a medical facility. Sound and Vibration, 40(12), 10-19.
Thornton, William R. ; Trethewey, Martin Wesley ; Maynard, Kenneth P. ; Sadler, James F. / Vibration isolation of a medical facility. In: Sound and Vibration. 2006 ; Vol. 40, No. 12. pp. 10-19.
@misc{2ac20c1bb6f940c5a086865b0ef0bdbb,
title = "Vibration isolation of a medical facility",
abstract = "The development of a vibration isolation system for a magnetic resonance imaging facility, University of Pittsburgh Medical Center (UPMC) Sports Performance Center, that was installed 50 ft from a busy heavy freight rail line is discussed. The UPMC wanted to eliminate all MRI operational disruptions caused by train traffic. An important task was to characterize the ground vibration at the MRI site due to the train traffic. The isolation system used an iterative process to optimize the design with regard to reduce vibration and cost. The vibration isolation approach required placing the MRI on a large inertial mass supported by a suspension with low rigid body resonant frequencies. The proposed UPMC Sports Performance Center also required to place the entire MRI room on an inertial mass and suspending it on a bed of helical coil. The continuous design refinement helped maximize isolation performance and periodic inspections ensured that isolation performance were not compromised.",
author = "Thornton, {William R.} and Trethewey, {Martin Wesley} and Maynard, {Kenneth P.} and Sadler, {James F.}",
year = "2006",
month = "12",
day = "1",
language = "English (US)",
volume = "40",
pages = "10--19",
journal = "Sound and Vibration",
issn = "1541-0161",
publisher = "Acoustical Publications Inc.",

}

Thornton, WR, Trethewey, MW, Maynard, KP & Sadler, JF 2006, 'Vibration isolation of a medical facility' Sound and Vibration, vol. 40, no. 12, pp. 10-19.

Vibration isolation of a medical facility. / Thornton, William R.; Trethewey, Martin Wesley; Maynard, Kenneth P.; Sadler, James F.

In: Sound and Vibration, Vol. 40, No. 12, 01.12.2006, p. 10-19.

Research output: Contribution to specialist publicationArticle

TY - GEN

T1 - Vibration isolation of a medical facility

AU - Thornton, William R.

AU - Trethewey, Martin Wesley

AU - Maynard, Kenneth P.

AU - Sadler, James F.

PY - 2006/12/1

Y1 - 2006/12/1

N2 - The development of a vibration isolation system for a magnetic resonance imaging facility, University of Pittsburgh Medical Center (UPMC) Sports Performance Center, that was installed 50 ft from a busy heavy freight rail line is discussed. The UPMC wanted to eliminate all MRI operational disruptions caused by train traffic. An important task was to characterize the ground vibration at the MRI site due to the train traffic. The isolation system used an iterative process to optimize the design with regard to reduce vibration and cost. The vibration isolation approach required placing the MRI on a large inertial mass supported by a suspension with low rigid body resonant frequencies. The proposed UPMC Sports Performance Center also required to place the entire MRI room on an inertial mass and suspending it on a bed of helical coil. The continuous design refinement helped maximize isolation performance and periodic inspections ensured that isolation performance were not compromised.

AB - The development of a vibration isolation system for a magnetic resonance imaging facility, University of Pittsburgh Medical Center (UPMC) Sports Performance Center, that was installed 50 ft from a busy heavy freight rail line is discussed. The UPMC wanted to eliminate all MRI operational disruptions caused by train traffic. An important task was to characterize the ground vibration at the MRI site due to the train traffic. The isolation system used an iterative process to optimize the design with regard to reduce vibration and cost. The vibration isolation approach required placing the MRI on a large inertial mass supported by a suspension with low rigid body resonant frequencies. The proposed UPMC Sports Performance Center also required to place the entire MRI room on an inertial mass and suspending it on a bed of helical coil. The continuous design refinement helped maximize isolation performance and periodic inspections ensured that isolation performance were not compromised.

UR - http://www.scopus.com/inward/record.url?scp=33846887607&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846887607&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:33846887607

VL - 40

SP - 10

EP - 19

JO - Sound and Vibration

JF - Sound and Vibration

SN - 1541-0161

ER -

Thornton WR, Trethewey MW, Maynard KP, Sadler JF. Vibration isolation of a medical facility. Sound and Vibration. 2006 Dec 1;40(12):10-19.