Abstract

In this study, an interface between a biological nerve fiber and an arbitrary electromechanical device was implemented using an analog VLSI-based amplifier/filter circuit. A silastic cuff was fitted over a live nerve bundle, and an electrode of Teflon coated silver wire was used to sense extracellular potentials. A dedicated CMOS VLSI-based circuit then filtered and amplified those signals to an amplitude appropriate for triggering an arbitrary circuit such as the four-phase stepper motor used in this study. In circuit tests, the amplifier/filter circuit was capable of sensing signals as low as 50 microvolts in an in vitro preparation of the optic nerve of limulus polyphemus, and effect rotation of the four-phase stepper motor with detected impulses. Using a silastic cuff electrode and dedicated VLSI circuitry for compactness and reliability, this circuit has excellent long term potential as a component of a surgically implanted system. It is also a pivotal first step in the implementation of a comprehensive cybernetic interface.

Original languageEnglish (US)
Pages (from-to)972-973
Number of pages2
JournalAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
Volume16
Issue numberpt 2
StatePublished - 1994

Fingerprint

Electrodes
Cybernetics
Horseshoe Crabs
Networks (circuits)
Polytetrafluoroethylene
Optic Nerve
Nerve Fibers
Silver
Equipment and Supplies
Electromechanical devices
Polytetrafluoroethylenes
baysilon
Optics
Wire
Fibers
In Vitro Techniques

All Science Journal Classification (ASJC) codes

  • Bioengineering

Cite this

@article{1d4a203e8b414e0b92fab73d250e579c,
title = "VLSI-based system for localization of extracellular potentials",
abstract = "In this study, an interface between a biological nerve fiber and an arbitrary electromechanical device was implemented using an analog VLSI-based amplifier/filter circuit. A silastic cuff was fitted over a live nerve bundle, and an electrode of Teflon coated silver wire was used to sense extracellular potentials. A dedicated CMOS VLSI-based circuit then filtered and amplified those signals to an amplitude appropriate for triggering an arbitrary circuit such as the four-phase stepper motor used in this study. In circuit tests, the amplifier/filter circuit was capable of sensing signals as low as 50 microvolts in an in vitro preparation of the optic nerve of limulus polyphemus, and effect rotation of the four-phase stepper motor with detected impulses. Using a silastic cuff electrode and dedicated VLSI circuitry for compactness and reliability, this circuit has excellent long term potential as a component of a surgically implanted system. It is also a pivotal first step in the implementation of a comprehensive cybernetic interface.",
author = "Seth Wolpert and Osborn, {Michael J.} and O'Neill, {A. Marie}",
year = "1994",
language = "English (US)",
volume = "16",
pages = "972--973",
journal = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",
issn = "1557-170X",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "pt 2",

}

VLSI-based system for localization of extracellular potentials. / Wolpert, Seth; Osborn, Michael J.; O'Neill, A. Marie.

In: Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, Vol. 16, No. pt 2, 1994, p. 972-973.

Research output: Contribution to journalArticle

TY - JOUR

T1 - VLSI-based system for localization of extracellular potentials

AU - Wolpert, Seth

AU - Osborn, Michael J.

AU - O'Neill, A. Marie

PY - 1994

Y1 - 1994

N2 - In this study, an interface between a biological nerve fiber and an arbitrary electromechanical device was implemented using an analog VLSI-based amplifier/filter circuit. A silastic cuff was fitted over a live nerve bundle, and an electrode of Teflon coated silver wire was used to sense extracellular potentials. A dedicated CMOS VLSI-based circuit then filtered and amplified those signals to an amplitude appropriate for triggering an arbitrary circuit such as the four-phase stepper motor used in this study. In circuit tests, the amplifier/filter circuit was capable of sensing signals as low as 50 microvolts in an in vitro preparation of the optic nerve of limulus polyphemus, and effect rotation of the four-phase stepper motor with detected impulses. Using a silastic cuff electrode and dedicated VLSI circuitry for compactness and reliability, this circuit has excellent long term potential as a component of a surgically implanted system. It is also a pivotal first step in the implementation of a comprehensive cybernetic interface.

AB - In this study, an interface between a biological nerve fiber and an arbitrary electromechanical device was implemented using an analog VLSI-based amplifier/filter circuit. A silastic cuff was fitted over a live nerve bundle, and an electrode of Teflon coated silver wire was used to sense extracellular potentials. A dedicated CMOS VLSI-based circuit then filtered and amplified those signals to an amplitude appropriate for triggering an arbitrary circuit such as the four-phase stepper motor used in this study. In circuit tests, the amplifier/filter circuit was capable of sensing signals as low as 50 microvolts in an in vitro preparation of the optic nerve of limulus polyphemus, and effect rotation of the four-phase stepper motor with detected impulses. Using a silastic cuff electrode and dedicated VLSI circuitry for compactness and reliability, this circuit has excellent long term potential as a component of a surgically implanted system. It is also a pivotal first step in the implementation of a comprehensive cybernetic interface.

UR - http://www.scopus.com/inward/record.url?scp=0028736315&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028736315&partnerID=8YFLogxK

M3 - Article

VL - 16

SP - 972

EP - 973

JO - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

JF - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

SN - 1557-170X

IS - pt 2

ER -